LXW Series Vortex Flowmeter
- Category:Marine Flow Meter
- Delivery Time:20-30 days.
- Fob Price:Get Latest Price Now
- Place of Origin:China
Details
General
LXW Series vortex flowmeter is manufactured according to the principle of Karman vortex principle together with latest digital transmitter (DSP technology). It is widely used to measure liquid, gas, steam flow in the closed pipeline because the original detection is sealed in the test body, no contact with the measured medium and there is no lining material and moving parting, it does not need on-site maintenance and it is very popular with the majority of users in industries of oil, petrochemical, water/waste water treatment, metallurgy, pharmacy, thermoelectric, etc. for process control and measurement management.
Feature And Main Technical Datum
Compact structure
No moving parts, long service time
Long time stability
Same sensor can measure liquid, gas and steam
With acceptable Reynold number, the meter coefficient is free from the influence of the change of temperature, pressure, viscosity and others.
Reynolds No. Range: 2104~7106 (For DN25~DN100)
4104~7106 (For DN150~DN300)
Display: to display instant and total Flow
Working Pressure: 1.6~32MPa
Medium Temp.: 0℃~150℃(Integral Type)
+100℃ ~+350℃(High temp. Type)
Ambient Temp.:-25℃~+60℃
Power:24VDC ± 10% or 220VAC
Relative Humidity: 5 % ~95 %
Atmospheric Pressure: 86~106KPa
Measurable Fluid: liquid, gas and steam
Accuracy: 1%(For Liquid), 1.5%(For Gas and Steam)
Output Signal: 4~20mA Current(2 Wire System) Or Standard Pulse Output(3 Wire System)
Digital Communication Modbus RTU
Analog signal
Anti-explosion Grade: Exd II BT4
Principle
Put a drum vertically into a burette and let some fluid flow down along the drum, by two sides of which there formed, in rotation, regular vortexes , which is called the Karman Vortex Street. An output frequency of the Karman Vortex Street is related to fluid velocity and drum diameter, which can be described by following formula:
f=St SHAPE\* MERGEFORMAT
Where,
f-Output frequency of the Karman Street
St-Coefficient (called as Strohar number)
v-velocity
d-Diameter of drum
As an output frequency of the Karman Vortex Street f is direct proportional to a velocity v. It may work out an instantaneous flow rate by using a tested output frequency of the Karman Street. The Strohar number is a key coefficient for vortex street flow meters. Within the lineal section of the curve, where St ≈0.17, the output frequency is direct proportional to the flow velocity, so a velocity v is derivable by using a tested frequency f.
LXW serials vortex street flow transducers detect the output frequency by using piezoeletricial elements inside the sensors (probes) to test the stress that is alternatively acted on the elements by vortex.
Tel: 86-23-68428875,68428422,68838417
Fax: 86-4008266163-88928
Email: sales@jinbomarine.com